6000 Not enough memory in line #n (x)

 6001 Invalid preprocess type x in line #n

 6002 Invalid postprocess type x in line #n

 6003 Invalid origin code x in line #n

 6004 Incorrect number of parameters in line #n

 6005 Unrecognized command in line #n

 6006 Command error(s) detected processing FS file x

An error was encountered processing the FS file.

 6007 WARNING: invalid display-box number d ignored in line #n

 6008 WARNING: file not found (d) in line #n of s

 6009 WARNING: duplicate command ignored, line #n of s

An error was encountered processing the FS file but it was not sufficiently serious to reject the fax send request. The transmission may not have been completed as expected.  The 6008 warning is only issued if the Ignore Missing COPIAFACTS run-time option is set.

 6010 Invalid mailbox in line #n of s

An invalid mailbox was specified for a fax poll operation.

 6011 License to use FFCLIENT not enabled in line #n of file %s

 6012 License to use FFMERGE not enabled in line #n of file %s

 6013 License to use CF8GCOVER not enabled in line #n of file %s

The FS file was generated from a CopiaFacts add-on product which has not been licensed for use on this system.

 6014 Outbound call aborted because of simultaneous inbound call

An inbound call was detected after an outbound operation had been scheduled for transmission on the same line, but just in time to stop the outbound call continuing, and to reset it to be picked up later or by another line.

 6015 WARNING: invalid delete option ignored in line #n

The $delete_option keyword was invalid or not correctly spelled.

 6016 FFCLIENT licensed for only n users in line #n of file x

 6017 License to use Document Converter not enabled in line #n of file x

The FS file was generated from a CopiaFacts add-on product which has not been licensed for use on this system.

 6018 Outbound call aborted because no free E1 telephony channel

There was no Dialogic telephony channel available on which to place the call. This sometimes occurs when a telephony channel is slow to clear or has become unavailable either on the board or at the CO.

 6019 Conditional Text syntax error {-13}

 6020 Include file not found {-12}

 6021 Required library FFPDF.DLL not found or failed to load {-11}

 6022 Exception while reading GCT watermark file {-10}

 6023 Exception in CF8GCOVER {-9}

 6024 Error writing GCT output file {-8}

 6025 Exception while writing GCT output file {-7}

 6026 Error reading GCT input TIFF file {-6}

 6027 Invalid GCT output filename {-5}

 6028 No free cache entry for GCT watermark

 6029 GCT Watermark file not found {-3}

 6030 GCT file has insufficient data {-2}

 6031 GCT file not found for conversion {-1}

 6032 Graphical cover creation failed (code n) for x

An error was detected in CF8GCOVER.DLL while processing graphical customization or TIF file transformation.  The negative numbers shown in { } are the error values returned by CF8GCOVER when called from the GCSINGLE utility.

 6033 Invalid e-mail option in line #n

 6034 Alternate body/text not preceded by body/text in line #n

 6035 Missing $email_address command

 6036 Cannot have both alt-body and alt-text in line #n

 6037 Cannot have both body and text in line #n

A syntax error was detected in processing an e-mail FS file

 6038 Multiple 'infobox' pre-process lines at line #n

 6039 Multiple 'infobox' post-process lines at line #n

Only a single infobox process of each type is allowed. You can instead chain multiple infobox files to process additional tasks.

 6040 Invalid convert options keyword in line #n

An incorrect keyword was given on a $convert_options command.

 6041 Invalid TOSEND directory number in line #n

 6042 Retry delays class letter must be A..H in line #n

 6043 Invalid characters in delay string in line #n

 6044 Partial-retry max time must be >=0, less than 2 days, in line #n

 6045 Partial-retry minimum completion invalid in line #n

A syntax error was detected in processing smart-retry settings

 6046 Invalid/missing DNS file x in line #n

There was a problem processing a do-not-send file specified on $dns_file.

 6047 Pre- or Post-Process command count exceeded in line #n

There is a limit of 8 on the number of pre and post process commands

 6048 Pre- and Post-Processes specify both DOS and NT for file x

A legacy DOS pre- or post-process remains active

 6049 Warning: original ACTIVE file for FS x not found (n)

An access-control file in the ACTIVE folder has probably been manually deleted.  Be sure to investigate the cause if this error occurs frequently.

 6050 Extension is .GCT or .GTT but CF8GCOVER has not been loaded in line #n of s

CF8GCOVER.DLL was not loaded at startup but a graphical cover was specified.

 6051 Unsupported e-mail security option in line #n

An invalid e-mail security option has been specified

 6052 Invalid date value x in line #n of file x ignored

The $fax_send_date was invalid.

 6053 Warning: ACTIVE file %s timestamp mismatch: expected n found n

Most likely you are sending long multi-page faxes and the $active_life is too short: add a command to increase it.

 6054 License for Security Features not enabled in line #n of file s

You have used a command which requires a missing license option.

 6055 Warning: $active_life command MUST specify a long enough period if you are sending many-page faxes

See 6053 above.

6060,   "Non-faxable file s, compression (tag 103) = n

6061,   "Non-faxable file s, samples per pixel (tag 115) = n

6062,   "Non-faxable file s, invalid tag list (IFD)

6063,   "Non-faxable file s, image width (tag 100) = n

6064,   "Non-faxable file s, invalid X/Y res (tags 11A,11B) = n/n

6065,   "Non-faxable file s, invalid X/Y res for BladeWare = n/n

6066,   "Non-faxable file s, photometric interpretation n (tag 106)

A file to be faxed is invalid.